*Reference programmes for Energy Label / Regulation 392/2012 /EU
Values are based on the default programme setting, with clean
air and bottom lter. For consumer tests, the door lter and
bottom lter need to be cleaned after each cycle.
The energy consumption and drying time may dier from the values
above.
PROGRAMME LOAD
(KG)
SPIN SPEED rpm HUMIDITY % ENERGY
CONSUMPTION (kWh)
DRYING TIME min
ECO COTTON *
7 1000 60 2.09 171
3.5 1000 60 1.15 100
ECO COTTON
7 800 70 2.47 181
7 1400 50 1.73 137
COTTON IRON DRY
7 800 70 1.95 158
7 1000 60 1.75 135
7 1400 50 1.55 119
SYNTHETICS CUPBOARD
DRY
3.5 1000 40 0.78 65
They depend on the operation conditions in your home (such as
voltage uctuation, mixture of textiles, humidity of the textiles after
spinning, load volume).
The values are determined according to European Norm 61121 and
refer to the default programme setting; changing the setting also
impacts the consumption data.
CONSUMPTION DATA
PRODUCT FICHE
WWW
The product che with energy data of this appliance can be
downloaded from Bauknecht Website docs. bauknecht. eu
HOW TO OBTAIN THE USE AND CARE GUIDE
>
WWW
Download the Use and Care Guide from our
website docs. bauknecht. eu (you can use this QR code),
specifying the product’s commercial code.
> Alternatively, contact our Client After-sales Service
400011032085
Printed in Italy
CONTACTING OUR AFTER‑SALES
SERVICE
You can nd our contact details in the
warranty manual. When contacting our
Client After-sales Service, please state the
codes provided on your product’s
identication plate.
xxxxxxxxxxxx
Power Consumption - Watts
Left-on mode
0.86
O-mode
0.35
Heat Pump System
This dryer is tted with a sealed heat pump system to dry your clothes.
To operate, the heat pump contains uorinated greenhouse gases
(Fgases) which are covered by the Kyoto Protocol. These F gases are
contained in a hermetically sealed unit. This sealed unit contains 0.28
kg of the F gas R134a which acts as a refrigerant.
GWP = 1430 (1 t CO).